summaryrefslogtreecommitdiff
path: root/plugins/ExternalAPI/m_shutdown.h
blob: 59a2f587dd3851bf9381984c13fb219b6fc58c8b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
/*

'AutoShutdown'-Plugin for
Miranda NG: the free IM client for Microsoft* Windows*

Copyright (ñ) 2012-15 Miranda NG project (http://miranda-ng.org),
Copyright (C) 2004-2007 H. Herkenrath

This program is free software; you can redistribute it and/or
modify it under the terms of the GNU General Public License
as published by the Free Software Foundation; either version 2
of the License, or (at your option) any later version.

This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
GNU General Public License for more details.

You should have received a copy of the GNU General Public License
along with this program (Shutdown-License.txt); if not, write to the Free Software
Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA  02111-1307, USA.
*/

#ifndef M_SHUTDOWN_H__
#define M_SHUTDOWN_H__

/******************************************************************/
/************************* SERVICES *******************************/
/******************************************************************/

/* Show settings dialog   v1.3.0.0+
Shows the dialog by which the shutdown watcher can be started.
If the dialog is already opened this brings it to foreground.
 wParam=lParam=0
Returns 0 on success, nonzero otherwise.
*/
#define MS_AUTOSHUTDOWN_SHOWSETTINGSDIALOG  "AutoShutdown/ShowSettingsDialog"

/* Initiate shutdown process   v1.3.0.0+
Initiates the shutdown process for a given shutdown type.
If another shutdown process is already pending it will return error.
Associated events: ME_AUTOSHUTDOWN_OKTOSHUTDOWN, ME_AUTOSHUTDOWN_SHUTDOWN
 wParam=shutdownType
 lParam=(LPARAM)(BOOL)fShowConfirmDlg (whether to show the warning dialog or not)
Returns 0 on success, nonzero otherwise.
*/
#define MS_AUTOSHUTDOWN_SHUTDOWN  "AutoShutdown/Shutdown"

/* shutdown types */
#define SDSDT_CLOSEMIRANDA         1  // close miranda process
#define SDSDT_SETMIRANDAOFFLINE    2  // set all protocols to offline
#define SDSDT_LOGOFF               3  // logoff from Windows
#define SDSDT_REBOOT               4  // reboot computer
#define SDSDT_SHUTDOWN             5  // shutdown Windows and power off
#define SDSDT_STANDBY              6  // standby mode
#define SDSDT_HIBERNATE            7  // hibernate mode
#define SDSDT_LOCKWORKSTATION      8  // lock the workstation
#define SDSDT_CLOSERASCONNECTIONS  9  // close all dialup connections
#define SDSDT_MAX                  9

/* Get shutdown type description   v1.4.0.0+
Gets a textual description of the given shutdown type.
 wParam=shutdownType
 lParam=flags (see GSTDF_* below)
Returns a static buffer of the description of the given shutdown type.
It does not need to be freed in any way.
The returned text is already translated.
Returns a pointer to a string on success, NULL on error.
*/
#define MS_AUTOSHUTDOWN_GETTYPEDESCRIPTION  "AutoShutdown/GetTypeDescription"

#define GSTDF_LONGDESC      0x0001  // returns a long description
#define GSTDF_UNICODE       0x0002  // returns a Unicode string
#define GSTDF_UNTRANSLATED  0x0004  // returns an untranslated string
#if defined(_UNICODE)
   #define GSTDF_TCHAR  GSTDF_UNICODE  // will return WCHAR*
#else
   #define GSTDF_TCHAR  0              // will return char*, as usual
#endif

/* Check if shutdown type is enabled   v1.4.0.0+
Tests if a specific shutdown type is activated and its use is possible
on the system. For example hibernate and stand-by modes are not available on
older versions of Windows (needs Windows ME/2000+).
Shutdown might also be prohibited by security restrictions.
This services checks it all.
However, there is no need to call this before calling MS_AUTOSHUTDOWN_SHUTDOWN.
MS_AUTOSHUTDOWN_SHUTDOWN will fail if the given shutdown type is not enabled.
 wParam=shutdownType
 lParam=0
Returns TRUE if the given shutdown type is enabled, FALSE otherwise.
*/
#define MS_AUTOSHUTDOWN_ISTYPEENABLED  "AutoShutdown/IsTypeEnabled"

/* Start shutdown watcher   v1.4.0.0+
Starts the watcher using the last settings specified on the dialog
shown by MS_AUTOSHUTDOWN_SHOWSETTINGSDIALOG.
Call MS_AUTOSHUTDOWN_SHOWSETTINGSDIALOG instead to offer
options about what watcher to use.
Associated event: ME_AUTOSHUTDOWN_WATCHERCHANGED
 wParam=lParam=0
Returns 0 on success, nonzero otherwise.
*/
#define MS_AUTOSHUTDOWN_STARTWATCHER  "AutoShutdown/StartWatcher"

/* Stop shutdown watcher   v1.4.0.0+
Stops the currently running watcher.
If the watcher is not running, it returns error.
Associated event: ME_AUTOSHUTDOWN_WATCHERCHANGED
 wParam=lParam=0
Returns 0 on success, nonzero otherwise.
*/
#define MS_AUTOSHUTDOWN_STOPWATCHER  "AutoShutdown/StopWatcher"

/* Check if watcher is running   v1.4.0.0+
Checks if the watcher is currently active or not.
 wParam=lParam=0
Returns TRUE if the watcher is enabled, FALSE otherwise.
*/
#define MS_AUTOSHUTDOWN_ISWATCHERENABLED  "AutoShutdown/IsWatcherEnabled"

/******************************************************************/
/************************** EVENTS ********************************/
/******************************************************************/

/* Disallow shutdown process (event)   v1.3.0.0+
Gets fired when MS_AUTOSHUTDOWN_SHUTDOWN is called.
Parmeters are the same as specified at the call to MS_AUTOSHUTDOWN_SHUTDOWN.
 wParam=shutdownType
 lParam=(LPARAM)(BOOL)fShowConfirmDlg
Return 0 to allow shutdown, 1 to disallow.
*/
#define ME_AUTOSHUTDOWN_OKTOSHUTDOWN  "AutoShutdown/OkToShutdown"

/* Shutdown process started (event)   v1.3.0.1+
Gets fired when ME_AUTOSHUTDOWN_OKTOSHUTDOWN was confirmed.
Parmeters are the same as specified at the call
to MS_AUTOSHUTDOWN_SHUTDOWN.
 wParam=shutdownType
 lParam=(LPARAM)(BOOL)fShowConfirmDlg
Unused, return always 0 here.
*/
#define ME_AUTOSHUTDOWN_SHUTDOWN  "AutoShutdown/ShutdownEvent"

/* Watcher changed (event)   v1.3.0.0+
Fired when MS_AUTOSHUTDOWN_STARTWATCHER or MS_AUTOSHUTDOWN_STOPWATCHER
is called.
 wParam=(WPARAM)(BOOL)fIsStarted (whether whe watcher is running now)
 lParam=0
Unused, return always 0 here.
*/
#define ME_AUTOSHUTDOWN_WATCHERCHANGED  "AutoShutdown/Watcher/Changed"


#ifndef SHUTDOWN_NOSETTINGS
#define SETTING_REMEMBERONRESTART_DEFAULT    0  // SDROR_RUNNING
#define SETTING_SHOWCONFIRMDLG_DEFAULT       1
#define SETTING_CONFIRMDLGCOUNTDOWN_DEFAULT  30 // seconds
#define SETTING_WEATHERSHUTDOWN_DEFAULT      0
#define SETTING_SMARTOFFLINECHECK_DEFAULT    1

#define SETTING_SHUTDOWNTYPE_DEFAULT         SDSDT_SHUTDOWN
#define SETTING_WATCHERFLAGS_DEFAULT         (SDWTF_SPECIFICTIME|SDWTF_ST_COUNTDOWN)
#define SETTING_COUNTDOWN_DEFAULT            30
#define SETTING_COUNTDOWNUNIT_DEFAULT        60 // x times countdown seconds
#define SETTING_TIMESTAMP_DEFAULT            (DWORD)(time(NULL)+(SETTING_COUNTDOWN_DEFAULT*SETTING_COUNTDOWNUNIT_DEFAULT))
#define SETTING_CPUUSAGETHRESHOLD_DEFAULT    90 // percent

#define SDWTF_SPECIFICTIME  0x0001
#define SDWTF_ST_TIME       0x0002
#define SDWTF_ST_COUNTDOWN  0x0004
#define SDWTF_ST_MASK       0x0006 /* bitmask for SDWTF_ST_* bits */
#define SDWTF_MESSAGE       0x0008
#define SDWTF_FILETRANSFER  0x0010
#define SDWTF_IDLE          0x0020
#define SDWTF_STATUS        0x0040
#define SDWTF_CPUUSAGE      0x0080
#define SDWTF_MASK          0x00FF /* bitmask for all SDWTF_* bits */

#define SDROR_RUNNING       3
#endif

#endif // M_SHUTDOWN_H